Place of Origin: | China |
Brand Name: | Techsafe |
Certification: | ISO,CE |
Model Number: | SH712BS |
Minimum Order Quantity: | 1 |
---|---|
Price: | USD 1 / pc |
Packaging Details: | CTN |
Delivery Time: | 7 days |
Payment Terms: | T/T,Western union, L/C |
Supply Ability: | 200pcs/week |
Material: | SUS304 | Color: | Red/yellow/green |
---|---|---|---|
Product Name: | Safety Shower And Eye Wash,Laboratory Safety PPE Emergency Shower Eye Wash,Stainless Steel Emergency Shower & Eye Wash,mergency Shower Double Eye Wash | Original Water: | Clean Or Leached Water,Drinking Water Or Filtered Water,and Pay Attention To Quality Guarantee Period |
Application: | Laboratory,lab Equipment | Name: | Eye Wash,safety Shower And Eye Wash New Product,Manufacturer China Vertical Safety Shower And Eye Wash Station,Safety Emergency Body Shower Eye Wash Station |
Size: | 750mm*300mm*250mm | Function: | Wash Eye +shower |
Usage: | Clean And Protect Eyes | Weight: | 10Kg/pc |
Standard: | ANSI Z358.1-2009 | Flow Control: | Eyewash Flow≥11.4L/Min |
Feature: | Strong Corrosion Resistance&easy Operation | Maximum Water Pressure: | 7 Bar |
Working Temperature: | 0℃-55℃ | Surface Treatment: | Polish Or High Gloss Epoxy Powder Coat |
Sprayheads With Protective Covers: | Yes |
SH712BS-Safety shower & eyewash station,SS304 Emergency shower
Item no.:SH712BS
Product name:Safety shower & eyewash station,SS304
Material:304 stainless steel
Sprayer head:,has dust shield cap,can be removed when eye wash operated
Bowl:ø300mm
Shower head:ø250mm
Valve:eye wash-1/2" & shower-1" ball valve;activated in 1 second
Pressure:0.2-0.6Mpa
More details,pls visit www.labppe.com
*The fault and solutions
No. | Conk out | Cause | Solution |
1 |
The eye wash shower outlet flux is small |
A the adjustment rob is overdo B the adjustment valve is blocked |
A turn the rob anti-clockwise B wash the valve |
2 | The eye wash shower outlet flux is large | The adjustment rob is under-do | Turn the rob clockwise |
3 | The seep in the bowl is more | The outlet is blocked | Remove the foreign object |
Emergency shower,Eyewash,eye wash,Eye wash stations,eye washing,safety showers,eye wash solution,bradley eye wash,Emergency eye wash station,Emergency safety shower,Eye safety,eye washer,
Personal Protective Equipment:Emergency shower & Safety eye wash,Drench shower,Safety shower,Face wash bath,Eyewash station,Emergency shower.OSHA,ANSI Z358.1-2004,CE certificate.ISO9001:2008.
Using environment
1. Where splashes dangerous substances, such as chemicals, dangerous goods, hazardous liquid, solid, etc.
2. The environment with pollution.
Where burning may occur.
Please take anti-freezing measures for the pipeline in cold areas.
Installation conditions
The rescue is effective within the radius of 10 or 15 meters, with at least three directions of work position, and with visible sign. And without obstacles in the surroundings for quick use.
Installed near the hazardous areas.
Within a radius of 1.5 meters of the composition eyewash, there should be no electric switches to avoid electrical short circuit.
The water supply of the eyewash should be clean tap water or water filtered with appropriate filter medium.
Please follow the product specification for the pipe diameter and connection, to ensure the equipment work correctly.
Installation requirements
Please refer to the installation diagram, wind the pipe joint with sealing tape (PTFE Teflon tape).
When installing the eyewash with a pedal, the height of pedal front from the ground cannot be more than 90 mm.
Please push the valve gently to rinse the eyes, the clean water will spray from the nozzle automatically, and reset the push valve and the dust cover after use.
Please pull down the valve rod to shower other parts of body, the water will spray from the shower head automatically, and reset the rod after use.
The product is used in emergency situations, to temporarily alleviate the damage of the harmful substances on human body; for further treatment, please follow doctor’s instructions.
Maintenance
The users must be knowledge trained and trial operation trained sufficiently before use.
The equipment should be checked regularly (once a week is recommended), and please investigate the cause and treat in time if problem is found.